@ -24,6 +24,7 @@ including our adjusted keyboard, to values obtained with the participant's own
|
|
|
|
|
keyboards.
|
|
|
|
|
|
|
|
|
|
\subsection{Preliminary telephone interview}
|
|
|
|
|
\label{sec:telephone_interview}
|
|
|
|
|
Some of the studies we found that researched implications of actuation force on
|
|
|
|
|
speed, preference or other metrics were published between 1984 and 2010. That is
|
|
|
|
|
why we wanted to ascertain if and how, with the advance of technology in recent
|
|
|
|
@ -84,7 +85,7 @@ actuation force is 35 g ($\approx$ 0.34 \gls{N}) the most common one is 50 g
|
|
|
|
|
|
|
|
|
|
\begin{figure}[ht]
|
|
|
|
|
\centering
|
|
|
|
|
\includegraphics[width=0.8\textwidth]{images/keyswitches_brands}
|
|
|
|
|
\includegraphics[width=0.9\textwidth]{images/keyswitches_brands}
|
|
|
|
|
\caption{Available actuation forces for keyswitches of major keyswitch manufacturers}
|
|
|
|
|
\label{fig:keyswitches_brands}
|
|
|
|
|
\end{figure}
|
|
|
|
@ -133,9 +134,9 @@ and \textit{Z} can be observed in Figure \ref{fig:FM_example}.
|
|
|
|
|
The results of the measurements are given in Table \ref{tbl:finger_force}. The
|
|
|
|
|
median of the means (15.47 N) of all measurements was used to calculate the
|
|
|
|
|
actuation forces in gram for the keyswitches later incorporated in the layout
|
|
|
|
|
for adjusted keyboard. We used Eq. (\ref{eq:N_to_g}) and
|
|
|
|
|
Eq. (\ref{eg:actuation_forces}) to calculate the gram values for each measured
|
|
|
|
|
keyswitch.
|
|
|
|
|
for the adjusted keyboard. We used Eq. (\ref{eq:N_to_g}) and
|
|
|
|
|
Eq. (\ref{eq:actuation_forces}) to calculate the theoretical gram values for
|
|
|
|
|
each measured keyswitch.
|
|
|
|
|
|
|
|
|
|
\begin{equation}
|
|
|
|
|
\label{eq:N_to_g}
|
|
|
|
@ -161,45 +162,395 @@ key can be seen in Eq. (\ref{eq:force_example}).
|
|
|
|
|
AF_{P} = GFR * MAF_{P} = 3.23 \frac{g}{N} * 10.45 N \approx 33.75 g
|
|
|
|
|
\end{equation}
|
|
|
|
|
|
|
|
|
|
Because there are only certain spring
|
|
|
|
|
We then assigned the each theoretical actuation force to a group that resembles
|
|
|
|
|
a spring resistance which is available on the market or can be adjusted to that
|
|
|
|
|
value. We matched the results from Table \ref{tbl:finger_force} to the groups
|
|
|
|
|
representing the best fit shown in Table \ref{tbl:force_groups}.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
% Custom spring stiffness
|
|
|
|
|
% https://www.engineersedge.com/spring_comp_calc_k.htm
|
|
|
|
|
% https://www.eng-tips.com/viewthread.cfm?qid=198360
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
\begin{table*}[]
|
|
|
|
|
\begin{table}
|
|
|
|
|
\centering
|
|
|
|
|
\ra{1.3}
|
|
|
|
|
\begin{tabularx}{13cm}{?l^l^l^l^l^l^l^l}
|
|
|
|
|
\begin{tabular}{?l^l^l^l^l^l^l^l^l^l^l}
|
|
|
|
|
\toprule
|
|
|
|
|
\multicolumn{8}{c}{\textbf{Bottom Row}}\\
|
|
|
|
|
\textbf{Bottom Row} & \multicolumn{2}{c}{\emph{F5}} & \phantom{.} & \multicolumn{1}{c}{\emph{F4}} & \phantom{.} & \multicolumn{1}{c}{\emph{F3}} & \phantom{.} &\multicolumn{3}{c}{\emph{F2}}\\
|
|
|
|
|
\cmidrule{2-3}\cmidrule{5-5}\cmidrule{7-7}\cmidrule{9-11}
|
|
|
|
|
\rowstyle{\itshape}
|
|
|
|
|
\emph{Key} & ↑ & - & : & ; & M & N & B \\
|
|
|
|
|
Key & ↑ & - && : && ; && M & N & B \\
|
|
|
|
|
\midrule
|
|
|
|
|
\emph{Mean Force (N)} & 11.23 & 10.84 & 14.22 & 15.34 & 16.38 & 15.6 & 14.36\\
|
|
|
|
|
\emph{Actuation Force (g)} & 36.05 & 34.8 & 45.65 & 49.24 & 52.58 & 50.08 & 46.1\\
|
|
|
|
|
\end{tabularx}
|
|
|
|
|
\begin{tabularx}{13cm}{?l^l^l^l^l^l^l^X}
|
|
|
|
|
\multicolumn{8}{c}{\textbf{Home Row}}\\
|
|
|
|
|
\emph{Mean Force (N)} & 11.23 & 10.84 && 14.22 && 15.34 && 16.38 & 15.60 & 14.36\\
|
|
|
|
|
\emph{Actuation Force (g)} & 36.27 & 35.01 && 45.93 && 49.55 && 52.91 & 50.39 & 46.38\\
|
|
|
|
|
\end{tabular}
|
|
|
|
|
\begin{tabular}{?l^l^l^l^l^l^l^l^l^l^l}
|
|
|
|
|
\\
|
|
|
|
|
\textbf{Home Row} & \multicolumn{2}{c}{\emph{F5}} & \phantom{.} & \multicolumn{1}{c}{\emph{F4}} & \phantom{.} & \multicolumn{1}{c}{\emph{F3}} & \phantom{.} &\multicolumn{2}{c}{\emph{F2}}\\
|
|
|
|
|
\cmidrule{2-3}\cmidrule{5-5}\cmidrule{7-7}\cmidrule{9-10}
|
|
|
|
|
\rowstyle{\itshape}
|
|
|
|
|
\emph{Key} & Ä & Ö & L & K & J & H &\\
|
|
|
|
|
Key & Ä & Ö && L && K && J & H &\\
|
|
|
|
|
\midrule
|
|
|
|
|
\emph{Mean Force (N)} & 11.88 & 12.27 & 15.84 & 18.56 & 17.78 & 18.43 &\\
|
|
|
|
|
\emph{Actuation Force (g)} & 38.13 & 39.39 & 50.85 & 59.58 & 57.07 & 59.16 &\\
|
|
|
|
|
\end{tabularx}
|
|
|
|
|
\begin{tabularx}{13cm}{?l^l^l^l^l^l^l^l}
|
|
|
|
|
\multicolumn{8}{c}{\textbf{Top Row}}\\
|
|
|
|
|
\emph{Mean Force (N)} & 11.88 & 12.27 && 15.84 && 18.56 && 17.78 & 18.43 & \phantom{69.69}\\
|
|
|
|
|
\emph{Actuation Force (g)} & 38.37 & 39.63 && 51.16 && 59.95 && 57.43 & 59.53 &\\
|
|
|
|
|
\end{tabular}
|
|
|
|
|
\begin{tabular}{?l^l^l^l^l^l^l^l^l^l^l}
|
|
|
|
|
\\
|
|
|
|
|
\textbf{Top Row} & \multicolumn{3}{c}{\emph{F5}} & \phantom{.} & \multicolumn{1}{c}{\emph{F4}} & \phantom{.} & \multicolumn{1}{c}{\emph{F3}} & \phantom{.} &\multicolumn{2}{c}{\emph{F2}}\\
|
|
|
|
|
\cmidrule{2-4}\cmidrule{6-6}\cmidrule{8-8}\cmidrule{10-11}
|
|
|
|
|
\rowstyle{\itshape}
|
|
|
|
|
\emph{Key} & + & Ü & P & O & I & U & Z \\
|
|
|
|
|
Key & + & Ü & P && O && I && U & Z \\
|
|
|
|
|
\midrule
|
|
|
|
|
\emph{Mean Force (N)} & 10.8 & 10.7 & 10.45 & 14.34 & 17.95 & 17.0 & 16.8 \\
|
|
|
|
|
\emph{Actuation Force (g)} & 34.67 & 34.35 & 33.54 & 46.03 & 57.62 & 54.57 & 53.93\\
|
|
|
|
|
\emph{Mean Force (N)} & 10.80 & 10.70 & 10.45 && 14.34 && 17.95 && 17.00 & 16.80 \\
|
|
|
|
|
\emph{Actuation Force (g)} & 34.88 & 34.56 & 33.75 && 46.32 && 57.98 && 54.91 & 54.26\\
|
|
|
|
|
\bottomrule
|
|
|
|
|
\end{tabularx}
|
|
|
|
|
\end{tabular}
|
|
|
|
|
\caption{Maximum force measurements for all digits of the right hand in
|
|
|
|
|
different positions. The mean force of six participants is shown in the
|
|
|
|
|
first row of each table and the resulting actuation force for the
|
|
|
|
|
corresponding keyswitch in the following row. The columns indicate the label
|
|
|
|
|
of the scale on the measuring device which can be seen in Figure
|
|
|
|
|
\ref{fig:FM_example}. \textit{↑} stands for the shift key.}
|
|
|
|
|
\end{table*}
|
|
|
|
|
\ref{fig:FM_example}. \textit{↑} stands for the shift key. \textit{F5} :=
|
|
|
|
|
little finger, ..., \textit{F2} := index finger}
|
|
|
|
|
\label{tbl:finger_force}
|
|
|
|
|
\end{table}
|
|
|
|
|
|
|
|
|
|
\begin{table}
|
|
|
|
|
\centering
|
|
|
|
|
\ra{1.3}
|
|
|
|
|
\begin{tabular}{?l^c^c^c^c^c^c^c}
|
|
|
|
|
\toprule
|
|
|
|
|
\rowstyle{\itshape}
|
|
|
|
|
\textbf{Spring Stiffness:} & 35 g & 40 g & 45 g & 50 g & 55 g & 60 g \\
|
|
|
|
|
\midrule
|
|
|
|
|
\emph{\textbf{F5:} Key (g)} & \centered{P&(33.75)\\Ü&(34.56)\\+&(34.56)\\-&(35.01)\\↑&(36.27)}& \centered{Ä&(38.37)\\Ö&(39.63)}&&&&&\\
|
|
|
|
|
\midrule
|
|
|
|
|
\emph{\textbf{F4:} Key (g)} &&& \centered{:&(45.93)\\O&(46.32)} &\centered{L&(51.16)}&&\\
|
|
|
|
|
\midrule
|
|
|
|
|
\emph{\textbf{F3:} Key (g)} &&&&\centered{;&(49.55)}&&\centered{I&(57.98)\\K&(59.95)}\\
|
|
|
|
|
\midrule
|
|
|
|
|
\emph{\textbf{F2:} Key (g)} &&&\centered{B&(46.38)}&\centered{N&(50.39)\\M&(52.91)}&\centered{Z&(54.26)\\U&(54.91)\\J&(57.43)}&\centered{H&(59.53)}\\
|
|
|
|
|
\bottomrule
|
|
|
|
|
\end{tabular}
|
|
|
|
|
\caption{Categorization of theoretical actuation forces acquired with
|
|
|
|
|
Eq. (\ref{eq:actuation_forces}), into groups of more commonly available
|
|
|
|
|
stiffnesses of springs. The rows indicate which finger is used to press the
|
|
|
|
|
key. \textit{F5} := little finger, ..., \textit{F2} := index finger}
|
|
|
|
|
\label{tbl:force_groups}
|
|
|
|
|
\end{table}
|
|
|
|
|
|
|
|
|
|
We simply mirrored the results of the right hand, for keys operated by the left
|
|
|
|
|
hand and copied the values to keys which are out of reach without lifting the
|
|
|
|
|
hand. Finally, we created the adjusted keyboard layout that can be examined in
|
|
|
|
|
Figure \ref{fig:adjusted_layout}. This layout was used in our main experiment
|
|
|
|
|
where we compared it to four different keyboards with uniform actuation forces
|
|
|
|
|
which is discussed in more detail in the following section.
|
|
|
|
|
|
|
|
|
|
\begin{figure}[ht]
|
|
|
|
|
\centering
|
|
|
|
|
\includegraphics[width=1.0\textwidth]{images/adjusted_layout}
|
|
|
|
|
\caption{Adjusted keyboard layout based on the measurements conducted in this section}
|
|
|
|
|
\label{fig:adjusted_layout}
|
|
|
|
|
\end{figure}
|
|
|
|
|
|
|
|
|
|
\subsection{Main user study}
|
|
|
|
|
\label{sec:main_study_meth}
|
|
|
|
|
\subsubsection{Hypotheses}
|
|
|
|
|
\label{sec:main_hypotheses}
|
|
|
|
|
Based on the literature review and preliminary telephone interviews, we derived
|
|
|
|
|
the following hypotheses concerning the impact of actuation force on different
|
|
|
|
|
metrics related to performance and user experience to ultimately answer our
|
|
|
|
|
research question―\textit{``Does an adjusted actuation force per key have a positive
|
|
|
|
|
impact on efficiency and overall satisfaction while using a mechanical
|
|
|
|
|
keyboard?.''}
|
|
|
|
|
|
|
|
|
|
\begin{longtable}{p{0.3cm} p{0.5cm} p{13cm} p{0.5cm}}
|
|
|
|
|
& \textbf{H1} & Lower key actuation force improves typing speed over higher key actuation force (efficiency - speed). & \\
|
|
|
|
|
\\
|
|
|
|
|
& \textbf{H2} & Higher key actuation force decreases typing errors compared to lower key actuation force (efficiency - error rate). & \\
|
|
|
|
|
\\
|
|
|
|
|
& \textbf{H3} & Keys with lower actuation force are perceived as more satisfactory to type with than keys with higher actuation force. & \\
|
|
|
|
|
\\
|
|
|
|
|
& \textbf{H4} & An adjusted keyboard (non-uniform actuation forces) improves typing speed compared to standard keyboards (uniform actuation forces) (efficiency - speed).& \\
|
|
|
|
|
\\
|
|
|
|
|
& \textbf{H5} & An adjusted keyboard decreases typing errors compared to standard keyboards (efficiency - error rate).& \\
|
|
|
|
|
\\
|
|
|
|
|
& \textbf{H6} & An adjusted keyboard is perceived as more satisfactory to type with compared to standard keyboards. & \\
|
|
|
|
|
\\
|
|
|
|
|
& \textbf{H7} & Differences in actuation force influence muscle activity while typing. & \\
|
|
|
|
|
\end{longtable}
|
|
|
|
|
|
|
|
|
|
\subsubsection{Method}
|
|
|
|
|
\label{sec:main_method}
|
|
|
|
|
In our laboratory study, twenty-four participants were required to perform two
|
|
|
|
|
typing test with each of the four keyboards provided by us and two extra typing
|
|
|
|
|
test with their own keyboards as a reference. The four keyboards differed only
|
|
|
|
|
in actuation force and were the independent variable. The dependent variable
|
|
|
|
|
were, typing speed (\gls{WPM} and \gls{KSPS}), error rate (\gls{CER}, \gls{TER})
|
|
|
|
|
and satisfaction (preference, usability, comfort, forearm muscle activity
|
|
|
|
|
measured via \gls{EMG}, post experiment semi structured interview and ux-curves)
|
|
|
|
|
|
|
|
|
|
\subsubsection{Participants}
|
|
|
|
|
\label{sec:main_participants}
|
|
|
|
|
There were no specific eligibility criteria for participants (n=24) of this
|
|
|
|
|
study beside the ability to type on a keyboard for longer durations and with all
|
|
|
|
|
ten fingers. The style used to type was explicitly not restricted to schoolbook
|
|
|
|
|
touch typing to also evaluate possible effects of the adjusted keyboard on
|
|
|
|
|
untrained typists. All participants recruited were personal contacts. 54\% of
|
|
|
|
|
subjects were females. Participant's ages ranged from 20 to 58 years with a mean
|
|
|
|
|
age of 29. Sixteen out of the twenty-four subjects (67\%) reported that they
|
|
|
|
|
were touch typists. Subjects reported the following keyboard types as their
|
|
|
|
|
daily driver, notebook keyboard (12, 50\%), external keyboard (11, 46\%) and
|
|
|
|
|
split keyboard (1, 4\%). The keyswitch types of those keyboards were distributed
|
|
|
|
|
as follows: scissor-switch (13, 54\%), rubber dome (8, 33\%) and mechanical
|
|
|
|
|
keyswitches (3, 13\%). We measured the actuation force of each participants own
|
|
|
|
|
keyboard and the resulting distribution of actuation forces can be observed in
|
|
|
|
|
Figure \ref{fig:main_actuation_force}. The self-reported average daily usage of
|
|
|
|
|
a keyboard ranged from 1 hour to 13 hours, with a mean of 6.69 hours. As already
|
|
|
|
|
mentioned in Section \ref{sec:telephone_interview} it is important to note, that
|
|
|
|
|
a study by Mikkelsen et al. found, that self-reported durations related to
|
|
|
|
|
computer work can be inaccurate \cite{mikkelsen_duration}. All participants used
|
|
|
|
|
the \gls{QWERTZ} layout and therefore were already used to the layout used
|
|
|
|
|
throughout the experiment.
|
|
|
|
|
|
|
|
|
|
\begin{figure}[ht]
|
|
|
|
|
\centering
|
|
|
|
|
\includegraphics[width=0.8\textwidth]{images/main_actuation_force}
|
|
|
|
|
\caption{Distribution of actuation forces from participant's own
|
|
|
|
|
keyboards. The colors represent the type of keyboard. \textit{EXT:} external
|
|
|
|
|
keyboard, \textit{NOTE:} notebook, \textit{SPLIT}, split keyboard}
|
|
|
|
|
\label{fig:main_actuation_force}
|
|
|
|
|
\end{figure}
|
|
|
|
|
|
|
|
|
|
\subsubsection{Experimental Environment}
|
|
|
|
|
\label{sec:main_environment}
|
|
|
|
|
The whole experiments took place in a room normally used as an office. Chair,
|
|
|
|
|
and table were both height adjustable. The armrests of the chair were also
|
|
|
|
|
adjustable in height and horizontal position. The computer used for all
|
|
|
|
|
measurements featured an Intel i7-5820K (12) @ 3.600GHz processor, 16 GB RAM and
|
|
|
|
|
a NVIDIA GeForce GTX 980 Ti graphics card. The operating system on test machine
|
|
|
|
|
was running \textit{Arch Linux}\footnote{\url{https://archlinux.org/}}
|
|
|
|
|
(GNU/Linux, Linux kernel version: 5.11.16). The setup utilized two 1080p (Full
|
|
|
|
|
HD, Resolution: 1920x1080, Refresh-rate: 144Hz) monitors were participants were
|
|
|
|
|
allowed to adjust the angle, height and brightness prior to the start of the
|
|
|
|
|
experiment. The only two applications that were used during the experiment were
|
|
|
|
|
the typing test application described in Section \ref{sec:gott} inside of the
|
|
|
|
|
\textit{Chromium}\footnote{\url{http://www.chromium.org/Home}} browser (Version:
|
|
|
|
|
v90.0.4430.93-r857950) and \textit{FlexVolt
|
|
|
|
|
Viewer}\footnote{\url{https://www.flexvoltbiosensor.com/software/}} (Version:
|
|
|
|
|
0.2.15, Chrome App). The FlexVolt Viewer app was used to collect \gls{EMG} data
|
|
|
|
|
via a bluetooth dongle (\textit{Plugable USB 2.0 Bluetooth®
|
|
|
|
|
Adapter}\footnote{\url{https://plugable.com/products/usb-bt4le/}}) from the
|
|
|
|
|
\textit{FlexVolt 8-Channel Bluetooth Sensor}. Because of the ongoing COVID-19
|
|
|
|
|
pandemic\footnote{\url{https://www.who.int/emergencies/diseases/novel-coronavirus-2019}},
|
|
|
|
|
we ensured proper ventilation of the room and all participants including the
|
|
|
|
|
researchers were tested with antigen tests prior to every appointment.
|
|
|
|
|
|
|
|
|
|
\subsubsection{Independent Variable: Keyboards}
|
|
|
|
|
\label{sec:main_keyboards}
|
|
|
|
|
Additionally to the reference tests conducted with the participant's own
|
|
|
|
|
keyboards, we provided four keyboards which only differed in terms of actuation
|
|
|
|
|
force. We decided to assign pseudonyms in the form of Greek goddesses to the
|
|
|
|
|
keyboards to make fast differentiation during the sessions easier and reduce
|
|
|
|
|
ambiguity. The pseudonyms for each keyboard and the corresponding actuation
|
|
|
|
|
force can be found in Table \ref{tbl:kb_pseudo}. All keyboards used the standard
|
|
|
|
|
ISO/IEC 9995 \cite{iso9995-2} physical layout and provided keycaps representing
|
|
|
|
|
the German \gls{QWERTZ} layout, which all participants were already familiar
|
|
|
|
|
with. All four keyboards used in the experiment were
|
|
|
|
|
\textit{\gls{GMMK}}\footnote{\url{https://www.pcgamingrace.com/products/gmmk-full-brown-switch}}
|
|
|
|
|
equipped with \textit{Gateron} mechanical
|
|
|
|
|
keyswitches\footnote{\url{http://www.gateron.com/col/58459?lang=en}}. The order
|
|
|
|
|
in which participants would use the four keyboards during the experiment was
|
|
|
|
|
defined by a balanced latin square to reduce order effects. Additionally, the
|
|
|
|
|
mentioned reference tests with \textit{Own} were conducted at the start and end
|
|
|
|
|
of each session to detect possible differences in performance due to
|
|
|
|
|
exhaustion. The resulting groups used during the whole experiment were as
|
|
|
|
|
follows:
|
|
|
|
|
|
|
|
|
|
\begin{itemize}
|
|
|
|
|
\item \textbf{Group 1:} \textit{Own $\rightarrow$ Hera $\rightarrow$ Athena $\rightarrow$ Nyx
|
|
|
|
|
$\rightarrow$ Aphrodite $\rightarrow$ Own}
|
|
|
|
|
\item \textbf{Group 2:} \textit{Own $\rightarrow$ Athena $\rightarrow$ Aphrodite $\rightarrow$ Hera
|
|
|
|
|
$\rightarrow$ Nyx $\rightarrow$ Own}
|
|
|
|
|
\item \textbf{Group 3:} \textit{Own $\rightarrow$ Aphrodite $\rightarrow$ Nyx $\rightarrow$ Athena
|
|
|
|
|
$\rightarrow$ Hera $\rightarrow$ Own}
|
|
|
|
|
\item \textbf{Group 4:} \textit{Own $\rightarrow$ Nyx $\rightarrow$ Hera $\rightarrow$ Aphrodite
|
|
|
|
|
$\rightarrow$ Athena $\rightarrow$ Own}
|
|
|
|
|
\end{itemize}
|
|
|
|
|
|
|
|
|
|
\begin{table}
|
|
|
|
|
\centering
|
|
|
|
|
\ra{1.3}
|
|
|
|
|
\begin{tabular}{?l^l^l^l}
|
|
|
|
|
\toprule
|
|
|
|
|
\rowstyle{\itshape}
|
|
|
|
|
Pseudonym & Actuation Force && Description\\
|
|
|
|
|
\midrule
|
|
|
|
|
\textbf{Own} & 35 g - 65 g & $\approx$ 0.34 N - 0.64 N & Participant's own keyboard (Figure \ref{fig:main_actuation_force})\\
|
|
|
|
|
\textbf{Nyx} & 35 g & $\approx$ 0.34 N & Uniform\\
|
|
|
|
|
\textbf{Aphrodite} & 50 g & $\approx$ 0.49 N & Uniform\\
|
|
|
|
|
\textbf{Athena} & 80 g & $\approx$ 0.78 N & Uniform\\
|
|
|
|
|
\textbf{Hera} & 35 g - 60 g & $\approx$ 0.34 N - 0.59 N & Non-uniform / Adjusted (Figure \ref{fig:adjusted_layout})\\
|
|
|
|
|
\bottomrule
|
|
|
|
|
\end{tabular}
|
|
|
|
|
\caption{Pseudonyms used for the keyboards throughout the experiment.}
|
|
|
|
|
\label{tbl:kb_pseudo}
|
|
|
|
|
\end{table}
|
|
|
|
|
|
|
|
|
|
\subsubsection{Experimental Design}
|
|
|
|
|
\label{sec:main_design}
|
|
|
|
|
\textbf{Preparation and Demographics}
|
|
|
|
|
|
|
|
|
|
The whole laboratory experiment was conducted over a total time span of 3
|
|
|
|
|
weeks. Participants were tested one at a time in sessions that in total took
|
|
|
|
|
$\approx$ 120 minutes. Prior to the evaluation of the different keyboards, the
|
|
|
|
|
participant was instructed to read the terms of participation which included
|
|
|
|
|
information about privacy, the \gls{EMG} measurements and questionnaires used
|
|
|
|
|
during the experiment. Next, participants filled out a pre-experiment
|
|
|
|
|
questionnaire to gather demographic and other relevant information e.g., touch
|
|
|
|
|
typist, average \gls{KB} usage per day, predominantly used keyboard type,
|
|
|
|
|
previous medical conditions affecting the result of the study e.g., \glsfirst{RSI},
|
|
|
|
|
\glsfirst{CTS}, etc. The full questionnaire can be observed in the appendix
|
|
|
|
|
\ref{app:gott}. Further, participants could adjust the chair, table and monitor
|
|
|
|
|
to a comfortable position.
|
|
|
|
|
|
|
|
|
|
\textbf{\gls{EMG} Measurements}
|
|
|
|
|
|
|
|
|
|
Since we measured muscle activity during all typing tests, electrodes were
|
|
|
|
|
placed on the \glsfirst{FDS}/\glsfirst{FDP} and \glsfirst{ED} of both
|
|
|
|
|
forearms. As already discussed in Section \ref{sec:meas_emg}, the main function
|
|
|
|
|
of the \gls{FDS} and \gls{FDP} is the flexion of the medial four digits, while
|
|
|
|
|
the \gls{ED} mainly extends the medial four digits. Therefore, these muscles are
|
|
|
|
|
primarily involved in the finger movements required for typing on a keyboard
|
|
|
|
|
\cite[650-653]{netter_anatomy}. We used ECG-Electrodes (Ag/AgCI/Solid Adhesive,
|
|
|
|
|
Pregelled, Size: 43mm) from TIGA-MED Deutschland
|
|
|
|
|
GmbH\footnote{\url{https://www.tiga-med.de/Diagnostik-Geraete/EKG-Elektroden-Zubehoer/EKG-Klebeelektrode-Festgel-50-Stueck-Pack}}.
|
|
|
|
|
To identify the correct locations for the electrodes, participants were
|
|
|
|
|
instructed to wiggle their fingers till contractions of the \gls{FDS}, \gls{FDP}
|
|
|
|
|
or \gls{ED} could be felt \cite{kim_typingforces}. A reference electrode was
|
|
|
|
|
placed next to the pisiform bone onto the dorsal side of the wrist. The
|
|
|
|
|
locations were then shaved and subsequently cleaned with alcohol before applying
|
|
|
|
|
the electrode. The distance between electrodes was 20mm. The correct placement
|
|
|
|
|
was then confirmed, by observing the data received by the \textit{FlexVolt
|
|
|
|
|
8-Channel Bluetooth Sensor} in the \textit{FlexVolt Viewer} application while
|
|
|
|
|
the participant performed flexion and extension of the wrist. The
|
|
|
|
|
\textit{FlexVolt 8-Channel Bluetooth Sensor} used following hardware settings to
|
|
|
|
|
record the data: 8-Bit sensor resolution, 32ms \gls{RMS} window size and
|
|
|
|
|
Hardware smoothing filter turned off. To gather reference values (100\%\gls{MVC}
|
|
|
|
|
and 0\%\gls{MVC}), which are used later to calculate the percentage of muscle
|
|
|
|
|
activity for each test, we performed three measurements. First, participants
|
|
|
|
|
were instructed to fully relax the \gls{FDS}, \gls{FDP} and \gls{ED} by
|
|
|
|
|
completely resting their forearms on the table. Second, participants exerted
|
|
|
|
|
maximum possible force with their fingers against the top of the table
|
|
|
|
|
(\gls{MVC} - flexion) and lastly, participants applied maximum possible force
|
|
|
|
|
with their fingers to the bottom of the table while resting their forearms on
|
|
|
|
|
their thighs (\gls{MVC} - extension). We decided to also measure 0\%\gls{MVC}
|
|
|
|
|
before and after each typing test and used these values to normalize the final
|
|
|
|
|
data instead of the 0\%\gls{MVC} we retrieved from the initial \gls{MVC}
|
|
|
|
|
measurements.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
\textbf{Familiarization with \glsfirst{GoTT} and the Keyboards}
|
|
|
|
|
|
|
|
|
|
Participants could familiarize themselves with the typing test application
|
|
|
|
|
(\gls{GoTT}) for up to five minutes with a keyboard that was not used during the
|
|
|
|
|
experiment. Further, representative of the other keyboard models used in the
|
|
|
|
|
experiment (\gls{GMMK}), participants could familiarize themselves with
|
|
|
|
|
Aphrodite (50 g). Additionally, because of a possible height difference between
|
|
|
|
|
\gls{GMMK} compared to notebook or other keyboards, participants were given the
|
|
|
|
|
choice to use wrist rests of adequate height in combination with all four
|
|
|
|
|
keyboards during the experiment. If during this process participants reported
|
|
|
|
|
that an electrode is uncomfortable and that it would influence the following
|
|
|
|
|
typing test, this electrode was relocated and the procedure in the last section
|
|
|
|
|
was repeated (Happened one time during the whole experiment).
|
|
|
|
|
|
|
|
|
|
\textbf{Texts Used for Typing Tests}
|
|
|
|
|
|
|
|
|
|
As described in Section \ref{sec:gott}, we acquired ten, non-overlapping, texts
|
|
|
|
|
so that every keyboard could be tested twice. The texts were labeled T0\_1,
|
|
|
|
|
T0\_2, T1\_1, ..., T4\_1, T4\_2 and could be selected before each typing
|
|
|
|
|
test. The order of the texts did not change during the experiment. All texts had
|
|
|
|
|
almost identical \gls{FRE} scores (mean = 80.10, SD = 0.48).
|
|
|
|
|
|
|
|
|
|
\textbf{Questionnaires}
|
|
|
|
|
|
|
|
|
|
To receive feedback about several aspects that define a satisfactory user
|
|
|
|
|
experience while using a keyboard, we decided to incorporate two questionnaires
|
|
|
|
|
into our experiment. The first questionnaire was the \glsfirst{KCQ} provided by
|
|
|
|
|
\cite[56]{iso9241-411} and was filled out after each individual typing test. The
|
|
|
|
|
second survey, that was filled out every time the keyboard was changed, was the
|
|
|
|
|
\glsfirst{UEQ-S} \cite{schrepp_ueq_handbook} with an additional question―``How
|
|
|
|
|
satisfied have you been with this keyboard?''―that could be answered with the
|
|
|
|
|
help of an \gls{VAS} ranging from 0 to 100 \cite{lewis_vas}. The short version
|
|
|
|
|
of the \gls{UEQ} was selected, because of the limited time participants had to
|
|
|
|
|
fill out the questionnaires in between typing tests (2 - 3 minutes) and also
|
|
|
|
|
because participants had to rate multiple keyboards in one session
|
|
|
|
|
\cite{schrepp_ueq_handbook}.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
\item Initial typing test with own keyboard. (5 min) \\
|
|
|
|
|
Adjusted follow-up ISO keyboard comfort questionnaire. (2 min) \\
|
|
|
|
|
Pause with light stretching exercises. (3 min)
|
|
|
|
|
|
|
|
|
|
\item \textbf{Main Part of the Experiment:} In this part the subject had
|
|
|
|
|
to take two, 5 minute, typing tests per keyboard, with a total of 4
|
|
|
|
|
keyboards (\textit{Nyx, Aphrodite, Athena, Hera}). After each typing
|
|
|
|
|
test, the subject had to fill out the post typing test survey
|
|
|
|
|
(\gls{KCQ}). Keyboards A, B and C are equipped with one set of
|
|
|
|
|
keyswitches and therefore each of the keyboards provides one of the
|
|
|
|
|
following, uniform, actuation forces across all keyswitches: 35 \gls{g},
|
|
|
|
|
50 \gls{g} or 80 \gls{g}. These specific values are the results of a
|
|
|
|
|
self conducted comparison between the product lines of most major
|
|
|
|
|
keyswitch manufacturers. The results shown in appendix
|
|
|
|
|
\ref{app:keyswitch} yield, that the lowest broadly available force for
|
|
|
|
|
keyswitches is 35 \gls{g}, the highest broadly available force is 80
|
|
|
|
|
\gls{g}, and the most common offered force is 50 \gls{g}. Keyboard D is
|
|
|
|
|
equipped with different zones of keyswitches that use appropriate
|
|
|
|
|
actuation forces according to finger strength differences and key
|
|
|
|
|
position. The keyboards used in this experiment are visually identical,
|
|
|
|
|
ISO/IEC 9995-1 conform \cite{iso9995-1} and provide a \gls{QWERTZ}
|
|
|
|
|
layout to resemble the subjects day-to-day layout and keyboard format as
|
|
|
|
|
close as possible. All keyboards are equipped with linear mechanical
|
|
|
|
|
keyswitches from one manufacturer to minimize differences in haptic and
|
|
|
|
|
sound while typing. To mitigate order effects, the order of the
|
|
|
|
|
keyboards is counterbalanced with the help of the latin square method
|
|
|
|
|
and the text snippets for the individual tests are randomized
|
|
|
|
|
\cite{statist_counterbalancing}. \textbf{(total: 80 min)}
|
|
|
|
|
|
|
|
|
|
\begin{enumerate}
|
|
|
|
|
\item \textbf{\gls{KB} A, Part 1:} Typing test. (5min) \\
|
|
|
|
|
Adjusted follow-up ISO keyboard comfort questionnaire. (2 min) \\
|
|
|
|
|
Pause with light stretching exercises. (3 min)
|
|
|
|
|
\item \textbf{\gls{KB} A, Part 2:} Typing test. (5min) \\
|
|
|
|
|
Adjusted follow-up ISO keyboard comfort questionnaire. (2 min) \\
|
|
|
|
|
Pause with light stretching exercises. (3 min)
|
|
|
|
|
\item \textbf{\gls{KB} C, Part 1:} Typing test. (5min) \\
|
|
|
|
|
Adjusted follow-up ISO keyboard comfort questionnaire. (2 min) \\
|
|
|
|
|
Pause with light stretching exercises. (3 min)
|
|
|
|
|
\item \textbf{\gls{KB} C, Part 2:} Typing test. (5min) \\
|
|
|
|
|
Adjusted follow-up ISO keyboard comfort questionnaire. (2 min) \\
|
|
|
|
|
Pause with light stretching exercises. (3 min)
|
|
|
|
|
\item \textbf{\gls{KB} B, Part 1:} Typing test. (5min) \\
|
|
|
|
|
Adjusted follow-up ISO keyboard comfort questionnaire. (2 min) \\
|
|
|
|
|
Pause with light stretching exercises. (3 min)
|
|
|
|
|
\item \textbf{\gls{KB} B, Part 2:} Typing test. (5min) \\
|
|
|
|
|
Adjusted follow-up ISO keyboard comfort questionnaire. (2 min) \\
|
|
|
|
|
Pause with light stretching exercises. (3 min)
|
|
|
|
|
\item \textbf{\gls{KB} D, Part 1:} Typing test. (5min) \\
|
|
|
|
|
Adjusted follow-up ISO keyboard comfort questionnaire. (2 min) \\
|
|
|
|
|
Pause with light stretching exercises. (3 min)
|
|
|
|
|
\item \textbf{\gls{KB} D, Part 2:} Typing test. (5min) \\
|
|
|
|
|
Adjusted follow-up ISO keyboard comfort questionnaire. (2 min) \\
|
|
|
|
|
Pause with light stretching exercises. (3 min)
|
|
|
|
|
\end{enumerate}
|
|
|
|
|
|
|
|
|
|
\item Post-Test semi-structured interview: The participant has to draw three
|
|
|
|
|
different UX curves \cite{kujala_ux_curve} to evaluate how fatigue,
|
|
|
|
|
performance and overall usability of the individual keyboards were perceived
|
|
|
|
|
during the experiment. While drawing the UX curve, participants should
|
|
|
|
|
describe their thought process. To reduce errors in the later evaluation of
|
|
|
|
|
the UX curves, the entire interview is recorded. (10 min)
|
|
|
|
|
|
|
|
|
|
\end{enumerate}
|
|
|
|
|